Lagging Protection
Under Insulation Anti-Corrosion Coating providing maximum
protection in the most aggressive environments.
Therma-Tech LG is not intended as a chemical
resistant coating system. However, there are certain situations
where the product may come into contact with chemical splashes
and fumes particularly in industrial and chemical locations.
The following is given as a guide in determining its suitability
under such circumstances.
The assessments given in this section are based solely on
the chemical resistance of Therma-Tech LG
and do not take account of the substrate.
KEY:
S = Satisfactory
NR = Not Recommended
| Chemicals |
Occasional Splashes |
Fumes |
| Acetic acid - 1% |
S |
S |
| Ammonium hydroxide - 5% |
S |
S |
| Ammonium sulphate sol. - 5% |
S |
S |
| Calcium chloride sol. - 5% |
S |
S |
| Hydrochloric acid - 5% |
S |
S |
| Calcium chloride sol. - 5% |
S |
S |
| Industrial alcohol |
S |
S |
| Mineral oil (Shell X-100) |
S |
S |
| Nitric acid - 1% |
S |
S |
| Nitric acid - 5% |
S |
S |
| Nitric acid - 10% |
NR |
NR |
| Petrol |
S |
S |
| Potassium dichromate |
S |
S |
| Potassium hydroxide - 5% |
NR |
NR |
| Sodium chloride - 5% |
S |
S |
| Sulphuric acid - 1% |
S |
S |
| Sulphuric acid - 5% |
S |
S |
| Sulphuric acid - 10% |
NR |
S |
| White Spirit |
S |
S |
KEY:
S = Satisfactory
NR = Not Recommended
Print
This Page (Opens in new window)
a "One Stop Solution" to ALL your pipe leakage problems
|